ThermoRawFileOptions#

class pyopenms.ThermoRawFileOptions#

Bases: object

Options for metadata-preserving Thermo RAW loading

__init__() → None#
__init__(arg: pyopenms.ThermoRawFileOptions, /) → None

Methods

Attributes

all_detectors

Export UV/PDA/analog detector traces and PDA spectra

centroid

Centroid profile scans (matches ThermoRawFileParser peak picking; FileHandler sets it)

charge_data

Export instrument-assigned centroid charges as an integer data array

checksum

Compute the SHA-1 of the source file for mzML provenance

first_scan

First scan number to load (0: from the first scan)

instrument_methods

Retain the embedded instrument method texts

last_scan

Last scan number to load (0: up to the last scan)

metadata_only

Load spectrum metadata only (no peaks are read)

ms_levels

MS levels to load (empty: all; PDA spectra have level 0)

noise_data

Export the independently sampled noise/baseline arrays

precursor_mz_max

Skip MSn scans whose first precursor m/z is at or above this

precursor_mz_min

Skip MSn scans whose first precursor m/z is below this

preserve_trailers

Retain all scan trailer label/value pairs

rt_max

Load scans with RT < rt_max (seconds)

rt_min

Load scans with rt_min <= RT (seconds)

skip_chromatograms

Do not load the TIC and detector chromatograms

property all_detectors: bool#

Export UV/PDA/analog detector traces and PDA spectra

property centroid: bool#

Centroid profile scans (matches ThermoRawFileParser peak picking; FileHandler sets it)

property charge_data: bool#

Export instrument-assigned centroid charges as an integer data array

property checksum: bool#

Compute the SHA-1 of the source file for mzML provenance

property first_scan: int#

First scan number to load (0: from the first scan)

property instrument_methods: bool#

Retain the embedded instrument method texts

property last_scan: int#

Last scan number to load (0: up to the last scan)

property metadata_only: bool#

Load spectrum metadata only (no peaks are read)

property ms_levels: list[int]#

MS levels to load (empty: all; PDA spectra have level 0)

property noise_data: bool#

Export the independently sampled noise/baseline arrays

property precursor_mz_max: float#

Skip MSn scans whose first precursor m/z is at or above this

property precursor_mz_min: float#

Skip MSn scans whose first precursor m/z is below this

property preserve_trailers: bool#

Retain all scan trailer label/value pairs

property rt_max: float#

Load scans with RT < rt_max (seconds)

property rt_min: float#

Load scans with rt_min <= RT (seconds)

property skip_chromatograms: bool#

Do not load the TIC and detector chromatograms