AbsoluteQuantitationMethod#
- class pyopenms.AbsoluteQuantitationMethod#
Bases:
objectHolds information about a quantitation method for absolute quantitation using Isotope Dilution Mass Spectrometry (IDMS). This includes calibration curve parameters, limits of detection (LOD), limits of quantitation (LOQ), and the transformation model used for concentration calculation
- __init__() None#
- __init__(arg: pyopenms.AbsoluteQuantitationMethod, /) None
Methods
__init__()checkLOD(value)Checks if the given value is within the limits of detection (LOD)
checkLOQ(value)Checks if the given value is within the limits of quantitation (LOQ)
Returns the component name (unique identifier for the analyte)
Returns the concentration units for the component
Returns the Pearson correlation coefficient of the calibration curve fit
Returns the feature name (e.g., peak_apex_int or peak_area)
Returns the internal standard name used for ratio calculation
getLLOD()Returns the lower limit of detection (LLOD)
getLLOQ()Returns the lower limit of quantitation (LLOQ)
Returns the number of points used in the calibration curve
Returns the transformation model type (e.g., linear, b_spline)
Returns the transformation model parameters
getULOD()Returns the upper limit of detection (ULOD)
getULOQ()Returns the upper limit of quantitation (ULOQ)
setComponentName(component_name)Sets the component name (unique identifier for the analyte)
setConcentrationUnits(concentration_units)Sets the concentration units for the component
Sets the Pearson correlation coefficient of the calibration curve fit
setFeatureName(feature_name)Sets the feature name (e.g., peak_apex_int or peak_area)
setISName(IS_name)Sets the internal standard name used for ratio calculation
setLLOD(llod)Sets the lower limit of detection (LLOD)
setLLOQ(lloq)Sets the lower limit of quantitation (LLOQ)
setNPoints(n_points)Sets the number of points used in the calibration curve
setTransformationModel(transformation_model)Sets the transformation model type (e.g., linear, b_spline)
Sets the transformation model parameters
setULOD(ulod)Sets the upper limit of detection (ULOD)
setULOQ(uloq)Sets the upper limit of quantitation (ULOQ)
- checkLOD(value: float) bool#
Checks if the given value is within the limits of detection (LOD)
- checkLOQ(value: float) bool#
Checks if the given value is within the limits of quantitation (LOQ)
- getComponentName() str#
Returns the component name (unique identifier for the analyte)
- getConcentrationUnits() str#
Returns the concentration units for the component
- getCorrelationCoefficient() float#
Returns the Pearson correlation coefficient of the calibration curve fit
- getFeatureName() str#
Returns the feature name (e.g., peak_apex_int or peak_area)
- getISName() str#
Returns the internal standard name used for ratio calculation
- getLLOD() float#
Returns the lower limit of detection (LLOD)
- getLLOQ() float#
Returns the lower limit of quantitation (LLOQ)
- getNPoints() int#
Returns the number of points used in the calibration curve
- getTransformationModel() str#
Returns the transformation model type (e.g., linear, b_spline)
- getTransformationModelParams() pyopenms.Param#
Returns the transformation model parameters
- getULOD() float#
Returns the upper limit of detection (ULOD)
- getULOQ() float#
Returns the upper limit of quantitation (ULOQ)
- setComponentName(component_name: str) None#
Sets the component name (unique identifier for the analyte)
- setConcentrationUnits(concentration_units: str) None#
Sets the concentration units for the component
- setCorrelationCoefficient(correlation_coefficient: float) None#
Sets the Pearson correlation coefficient of the calibration curve fit
- setFeatureName(feature_name: str) None#
Sets the feature name (e.g., peak_apex_int or peak_area)
- setISName(IS_name: str) None#
Sets the internal standard name used for ratio calculation
- setLLOD(llod: float) None#
Sets the lower limit of detection (LLOD)
- setLLOQ(lloq: float) None#
Sets the lower limit of quantitation (LLOQ)
- setNPoints(n_points: int) None#
Sets the number of points used in the calibration curve
- setTransformationModel(transformation_model: str) None#
Sets the transformation model type (e.g., linear, b_spline)
- setTransformationModelParams(transformation_model_params: pyopenms.Param) None#
Sets the transformation model parameters
- setULOD(ulod: float) None#
Sets the upper limit of detection (ULOD)
- setULOQ(uloq: float) None#
Sets the upper limit of quantitation (ULOQ)